ASTM F1264

Get Price Now

Some results are removed in response to a notice of local law requirement.For more information,please see here.Previous123456NextFlexural Fatigue- ASTM F1264-A3 Fixation Device -IMFD -

ASTM F1264 Annex 3 is a test method for bending fatigue testing of intramedullary fixation devices (IMFD).This cyclic 4 point bend test determines the fatigue life at a specified bending moment or estimates the fatigue strength for a specified number of cycles.1.) The four point bend fixture should be attached to a Universal Testing System andSome results are removed in response to a notice of local law requirement.For more information,please see here.12345NextASTM International - Standard References for ASTM F1264 ASTM F1264 - 16e1 Standard Specification and Test Methods for Intramedullary Fixation Devices.Citing ASTM Standards Citation data is made available by participants in CrossRefs Cited-by Linking service.A comprehensive list of citations to this standard are listed here.F1541 Some results are removed in response to a notice of local law requirement.For more information,please see here.

Recognized Consensus Standards

Dec 23,2019 ASTM F1264#0183;ASTM F1264-16 Standard Specification and Test Methods for Intramedullary Fixation Devices Scope/Abstract.1.1 This specification is intended to provide a characterization of the design and mechanical function of intramedullary fixation devices (IMFDs),specify labeling and material requirements,provide test methods for characterization of Recognized Consensus StandardsDec 23,2019 ASTM F1264#0183;ASTM F1264-16 Standard Specification and Test Methods for Intramedullary Fixation Devices Scope/Abstract.1.1 This specification is intended to provide a characterization of the design and mechanical function of intramedullary fixation devices (IMFDs),specify labeling and material requirements,provide test methods for characterization of Orthopaedic Devices - Medical Device Testing ServicesIntramedullary Fixation Device Stifness Tests ASTM F1264-16; Knee Replacement Strength and Endurance Tests ASTM F1800-12,ASTM F1223,ASTM F1672,ISO 14243-1 and ISO 14243-3; Metallic Bone Screw Strength Tests ASTM F543-13e1; Metallic Bone Staples ASTM F564-10 (2015) Nucleus Device Strength and Endurance Tests ASTM 2789-10,ASTM 2346-05

Mechanical Testing Standards of Orthopedic Implants

ASTM F1264-03(2012) (2012) Standard specification and test methods for intramedullary fixation devices.ASTM International,West Conshohocken Google Scholar.6.ASTM F1541-02(2011)e1 (2011) Standard specification and test methods for external skeletal fixation devices.Intramedullary Rods (ASTM F1264 F383) - ADMETASTM F383 and ASTM F1264 were developed to standardize the quality testing of this device and verify that the product will not fail post-surgery.ASTM F383 was first published in 1973 and has since been withdrawn on account of ASTM F1264s development.Intramedullary Fixation DevicesTesting objective is determining the stiffness of bone screws per ASTM F1264-16.Bending tests are performed at ambient air environment in displacement control.Bending fixture stiffness is measured,and its artifact is taken into account in bone screw stiffness calculations as shown here 1/(Screw-Fixture Stiffness)=1/((Screw Stiffness)+1

Intramedullary Fixation Devices

Testing objective is determining the stiffness of bone screws per ASTM F1264-16.Bending tests are performed at ambient air environment in displacement control.Bending fixture stiffness is measured,and its artifact is taken into account in bone screw stiffness calculations as shown here 1/(Screw-Fixture Stiffness)=1/((Screw Stiffness)+1 Implant Testing - EndoLabASTM F1264 Standard Specification and Test Methods for Intramedullary Fixation Devices.ISO 15142 Metal intramedullary nailing systems part 1 to 3 This specification is intended to provide a characterization of the design and mechanical function of intramedullary fixation devices (IMFDs) specify labeling and material requirements,provide Images of ASTM F1264 imagesASTM F1264 - 03 Standard Specification and Test Methods doi 10.1520/f1264-03 Citation Format ASTM F1264-03,Standard Specification and Test Methods for Intramedullary Fixation Devices,ASTM International,West Conshohocken,PA,2003,astm

Flexural fatigue - MassDevice

Jun 21,2010 ASTM F1264#0183;ASTM F1264 Annex 3 is a test method for bending fatigue testing of intramedullary fixation devices (IMFD).This cyclic,four-point bend test determines theFlexural Fatigue- ASTM F1264-A3 Fixation Device -IMFDASTM F1264 Annex 3 is a test method for bending fatigue testing of intramedullary fixation devices (IMFD).This cyclic 4 point bend test determines the fatigue life at a specified bending moment or estimates the fatigue strength for a specified number of cycles.Flexural Fatigue- ASTM F1264-A3 Fixation Device -IMFD -ASTM F1264 Annex 3 is a test method for bending fatigue testing of intramedullary fixation devices (IMFD).This cyclic 4 point bend test determines the fatigue life at a specified bending moment or estimates the fatigue strength for a specified number of cycles.1.) The four point bend fixture should be attached to a Universal Testing System and

ASTM-F1264,2016 - MADCAD

Description of ASTM-F1264 2016 1.1 This specification is intended to provide a characterization of the design and mechanical function of intramedullary fixation devices (IMFDs),specify labeling and material requirements,provide test methods for characterization of IMFD mechanical properties,and identify needs for further development of test ASTM-F1264,2012 - MADCADASTM F1264 - 03(2012) Standard Specification and Test Methods for Intramedullary Fixation Devices .Active Standard ASTM F1264 Developed by Subcommittee F04.21 .Book of Standards Volume 13.01ASTM-F1264,2000 - MADCADASTM F1264-00 Historical Standard ASTM F1264-00 Standard Specification and Test Methods for Intramedullary Fixation Devices .SUPERSEDED (see Active link,below) ASTM F1264 .1.Scope .1.1 This specification is intended to provide a characterization of the design and mechanical function of intramedullary fixation devices (IMFDs) specify

ASTM-F1264 Standard Specification and Test Methods for

ASTM-F1264 Standard Specification and Test Methods for Intramedullary Fixation Devices - bend testing; definitions; extraction; fatigue test; fracture fixation; implants; intramedullary fixation devices; orthopaedic medical device; performance; surgical devices; terminology; test methods; torsion test; trauma;; ICS Number Code 11.040.40 (Implants for surgery,prothetics and orthotics)ASTM Standards - Medical Device Testing ServicesASTM International,astm,is a globally recognized leader in the development and delivery of voluntary consensus standards.Its F04 committee on Medical and Surgical Materials and Devices delivers over 300 standards.MDT is an active ASTM memberASTM Medical Device Standards - ANSI WebstoreASTM F1264-16e1 Standard Specification and Test Methods for Intramedullary Fixation Devices.ASTM F565-04(2018) Standard Practice for Care and Handling of Orthopedic Implants and Instruments.ASTM F983-86(2018) Standard Practice for Permanent Marking of Orthopaedic Implant Components.

ASTM F383 and F1264 Intramedullary rods* - Innoproof

We offer you a characterization of the design and mechanical function of intramedullary nails according to the test standards ASTM F383 and F1264.Static four-point bending test The intramedullary nail is clamped into the test device and loaded until a sudden decrease in force occurs (fracture orASTM F383 and F1264 Intramedullary rods* - InnoproofWe offer you a characterization of the design and mechanical function of intramedullary nails according to the test standards ASTM F383 and F1264.Static four-point bending test The intramedullary nail is clamped into the test device and loaded until a sudden decrease in force occurs (fracture orASTM F1264:14 - standard.noASTM F1264:03(2012) Withdrawn Superseded by ASTM F1264:16 Withdrawn Number of pages 19 Price NOK 1 105,00 (excl.VAT) NOK 1 381,25 (with VAT) Scope TRUE/F1264 Adopted 2014-11-01

ASTM F1264-16e1_stdlibrary

astm f1264-16e1 Designation F1264 161Standard Specification and Test s forIntramedullary Fixation Devices1This standard is issued under the fixed designation F1264; the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.ASTM F1264-16e1_stdlibraryastm f1264-16e1 Designation F1264 161Standard Specification and Test s forIntramedullary Fixation Devices1This standard is issued under the fixed designation F1264; the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.ASTM F1264-16e1 - TechstreetASTM F1264-16e1 Standard Specification and Test Methods for Intramedullary Fixation Devices.standard by ASTM International,05/01/2016.View all product details Most Recent

ASTM F1264-16e1 - Standard Specification and Test

ASTM F1264-16e1 Standard Specification and Test Methods for Intramedullary Fixation Devices.1.1 This specification is intended to provide a characterization of the design and mechanical function of intramedullary fixation devices (IMFDs),specify labeling and material requirements,provide test methods for characterization of IMFD mechanical ASTM F1264-16ASTM F1264-16 Standard Specification and Test Methods for Intramedullary Fixation Devices.standard by ASTM International,05/01/2016.This document has been replaced.View the most recent version.ASTM F1264-16 - Standard Specification and Test Methods ASTM F1264-16 Standard Specification and Test Methods for Intramedullary Fixation Devices.1.1 This specification is intended to provide a characterization of the design and mechanical function of intramedullary fixation devices (IMFDs),specify labeling and material requirements,provide test methods for characterization of IMFD mechanical

ASTM F1264 Torsion Bend Fatigue Test Equipment for

ASTM F1264 provides specification of the design and mechanical properties associated with an Intramedullary Fixation Device (IMFD).An IMFD is a metal splint that is inserted inside of the bone into the medullary cavity,and held in place by locking screws.ASTM F1264 - Standard Specification and Test Methods for ASTM F1264 Standard Specification and Test Methods for Intramedullary Fixation Devices active,Most Current Buy Now.Details.History.References Organization ASTM Publication Date 1 May 2016 Status active Page Count 19 ICS Code (Implants for surgery,prosthetics and orthotics) 11.040.40 ASTM F1264 - 16e1 Standard Specification and Test Methods doi 10.1520/f1264-16e01 Citation Format ASTM F1264-16e1,Standard Specification and Test Methods for Intramedullary Fixation Devices,ASTM International,West Conshohocken,PA,2016,astm

ASTM F1264 - 16E1 - Standard Specification and Test

ASTM F1264 - 16E1 Title Standard Specification and Test Methods for Intramedullary Fixation Devices Status Current Publication Date 01 May 2016 Normative References(Required to achieve compliance to this standard) No other standards are normatively referenced Informative References(Provided for Information) No other standards are ASTM F1264 - 16E1 - Standard Specification and Test ASTM F1264 - 16E1 Title Standard Specification and Test Methods for Intramedullary Fixation Devices Status Current Publication Date 01 May 2016 Normative References(Required to achieve compliance to this standard) No other standards are normatively referenced Informative References(Provided for Information) No other standards are ASTM F1264 - 16 Standard Specification and Test Methods doi 10.1520/f1264-16 Citation Format ASTM F1264-16,Standard Specification and Test Methods for Intramedullary Fixation Devices,ASTM International,West Conshohocken,PA,2016,astm

ASTM F1264 - 03(2012) en - NEN

ASTM F1264 - 03(2012) en.Standard Specification and Test Methods for Intramedullary Fixation Devices.Deze norm is ingetrokken sinds 01-11-2014;ASTM F1264 Standard Specification and Test Methods for ASTM F1264 2016 Edition,May 1,2016.Complete Document Standard Specification and Test Methods for Intramedullary Fixation Devices Includes all amendments and changes through Editorial Change 1,November 2016.View Abstract Product Details Document History ASTM F1264 Orthopaedic Innovation CentreASTM F1264.ASTM F1264 quantity.Add to Quote.Prev.Test Methods for Intramedullary Fixation Devices .Describes four standard test methods static four-point bend,static torsion,bending fatigue test,bending fatigue test for locking screws.Not all tests outlined in this standard are applicable/required,but based on the intent of the

Main Products